CamGT 3V-600

  • Protège les turbines contre l’encrassement => meilleur rendement, réduction des lavages
  • Évolution lente de la perte de charge => meilleur rendement énergétique
  • Prévention de la corrosion due à l’humidité, au sel et aux substances agressives
  • Économies de carburant, augmentation de la puissance délivrée et du rendement
  • Faibles coûts de maintenance
  • Aucun risque de détérioration du compresseur
  • Aucun risque pour la turbine si la pression monte brutalement
  • Incinérable, non corrodable
  • ICON34 gasket_01_00_10
  • ICON3 efficiency guarantee
  • ICON5 Low Pressure Drop
  • ICON7 iso16890.ai
  • ICON9 en1822
  • ICON15 LCC optimized
  • ICON54 ISO 29461 icon
Article Classe ISO 16890 Classe de filtration EN779 Classe de filtration EN1822 Largeur (mm) Hauteur (mm) Profondeur (mm) Débit (m3/h) Perte de charge initiale (Pa) Classification des filtres ASHRAE US
CamGT 3V 600-T8-Std ePM1 70% F8 592 592 600 4250 95 MERV 14
CAM GT 3V 600-T9-Std ePM1 85% F9 592 592 600 4250 115 MERV 15
CamGT 3V 600-T10-Std E10 592 592 600 4250 135
CamGT 3V 600-T11-Std E11 592 592 600 4250 140
CAM GT 3V 600-T12-Std E12 592 592 600 4250 190
CamGT 3VCB 600-T12-Std E12 592 592 600 4250 190
CamGT 3V 600-T13-Std H13 592 592 600 4250 240
 L'outil de calcul de la perte de charge est disponible

Calculer la perte de charge

m3/h
= Pa
Débit d'air trop important pour ce filtre

Spécifications

Application
Admission d'air de turbines à gaz.
Cadre
Plastique PS moulé, ABS
Média
Fibre de verre
Max temperature (°C)
70°C
Humidite relative
100%
Perte de charge finale recommandée
600 Pa
Separator
Hot-melt
Joint
Polyuréthane coulé d'une pièce
Grille, aval
De renfort ABS
Sealant
Polyuréthane
Débit max
1,8 x débit nominal
Commentaire
Pression d'éclatement: > 6250 Pa
Classification des filtres ASHRAE US
MERV 15

Produits similaires

Articles liés CamGT

Significant Reduction in Compressor Efficiency Degradation

Les filtres camgt epa augmentent la performance des turbines à gaz

Les filtres à air à poches Hi-Flo et la mise à niveau des filtres à air CamGT EPA réduisent de 80 % la dégradation de l'efficacité des compresseurs, ce qui permet d'éviter 3 remplacements de filtres hors ligne, 7 remplacements de préfiltres en ligne et 3 lavages d'eau hors ligne par an.

Etudes de cas Turbomachines et Energie
Say Goodbye to Fouling and Pressure Spikes!

Say goodbye to fouling and pressure spikes!

CamGT 3V-600 static final filters and Cam-Flo GT Hybrid pocket air filters eliminate 6 offline washes per year, improve gas turbine compressor efficiency, and boost power output for a Singaporean coastal cogeneration power plant.

Etudes de cas Turbomachines et Energie

Engie midlothian (gdf suez) retrofit 

Camfil provides the CamGT EPA air filter solution that helps reduce gas turbine compressor efficiency degradation and improves pressure drop by 40%. Three years after installation, the customer reported no filter change-outs, only 1 water wash in 3 years, and a low and stable pressure drop.

Etudes de cas Turbomachines et Energie

Plant upgrades to the camgt 3v-600 for a 6-year lifecycle & to prevent engine degradation

Egat North, the largest energy producer in Thailand, upgraded to Hi-Flo and CamClose air intake pre-filters as well as CamGT final EPA air filters and lowered degradation by 70%, reduced water wash requirements, and saved approximately $1.24M USD per year.

Etudes de cas Fabrication machines Turbomachines et Energie

Gulf of thailand oil and gas

Frequent pressure and short filter replacement intervals led to high operational costs. Camfil's Cam-Flo air intake pre-filters and CamGT EPA air filters met their goal of 8000 hours of life and reduced pressure drop by 50%.

Etudes de cas Fabrication machines Turbomachines et Energie

Lng & air filtration

Air sampling, CamLab on-site analysis, as well as a Life Cycle Cost analysis show that the CamGT EPA filters will result in no shutdowns for turbine water washes, final filter shutdown extended to 5 years, decreased risk of corrosion and maximum power output.

Etudes de cas Turbomachines et Energie

Egat north power generation

Egat North, the largest energy producer in Thailand, upgraded to Hi-Flo and CamClose air intake pre-filters as well as CamGT final EPA air filters and lowered degradation by 70%, reduced water wash requirements, and saved approximately $1.24M USD per year.

Etudes de cas Turbomachines et Energie

Pacific coast energy plant

Case Study: An energy plant on the pacific coast upgrades to the camgt 4v-300 air inlet filters after tests show its water and salt handling capabilities.

Etudes de cas Turbomachines et Energie

Cutting the carbon cost with improved air inlet systems 

With a growing demand for greener practices, and rising operational costs, it has become imperative that gas turbine operators cut their carbon footprints. Upgraded air intake systems are one of the easiest, most cost-effective ways to meet these demands, while improving operations at the same time.

Turbomachines et Energie

Camfil Designs a Compact Solutions on Existing Offshore Platform for Foxtrot International that Reduces Gas Turbine Maintenance

Located offshore Ivory Coast, Africa, the CamGT EPA filter solution saves Foxtrot International 3 shutdowns per year and eliminates salt corrrosion, without compromising on footprint.

Etudes de cas Turbomachines et Energie

Modernisation de tata power, trombay

Tata Power Ltd, India's largest integrated power company requests Camfil for a Cam-Flo pocket bag filter and CamGT static air filter retrofit after heavy hot corrosion in the gas turbine and high pressure drop jeopardized performance and safety.

Etudes de cas Turbomachines et Energie

Dalkia passe à la classe epa

Dalkia, a leader in the French gas turbine market, launched a national comparative test for various air intake filters, including Camfil's Hi-Flo pre-filters and CamGT EPA filters, to increase power production for their 10 GE LM6000 gas turbines.

Etudes de cas Turbomachines et Energie

Les filtres camgt garantissent l’insonorisation et offrent des avantages supplémentaires grâce à la réduction de la perte de charge

Noise complaints from neighboring communities in Thailand prompted the plants to evaluate a noise-reducing filtration system. The CamGT high efficiency air filter solution not only improved the noise levels, it also increased turbine availability, improved pressure drop and helped the gas turbine produce more power.

Etudes de cas Turbomachines et Energie

Vous avez besoin d'entrer en contact avec quelqu'un au Canada ?
Fuseau horaire standard de l'Est
1-800-976-9382
Fuseau horaire du Pacifique (en anglais seulement)
1-877-919-3277
Trouver un contact