Vreckové filtre so zníženým počtom vreciek zo sklenných vlákien s plastovým rámom. Dostupné vo všetkých účinnostiach podľa ISO16890.
Typ položky | ISO hodnotenie ISO 16890 | Filtračná trieda EN779 | Šírka (mm) | Výška (mm) | Hĺbka (mm) | Prietok vzduchu (m3/h) | Počiatočná tlaková strata (Pa) | Energia (kWh/rok) | Energetická trieda (Eurovent) |
---|---|---|---|---|---|---|---|---|---|
5/640 | ePM10 60% | M5 | 592 | 592 | 640 | 3400 | 40 | 631 | B |
5/640 | ePM10 60% | M5 | 490 | 592 | 640 | 2800 | 40 | B | |
5/640 | ePM10 60% | M5 | 287 | 592 | 640 | 1700 | 40 | B | |
5/640 | ePM10 60% | M5 | 592 | 490 | 640 | 2800 | 40 | B | |
5/640 | ePM10 60% | M5 | 592 | 287 | 640 | 1700 | 40 | B | |
5/520 | ePM10 60% | M5 | 592 | 592 | 520 | 3400 | 45 | 836 | C |
5/520 | ePM10 60% | M5 | 490 | 592 | 520 | 2800 | 45 | C | |
5/520 | ePM10 60% | M5 | 287 | 592 | 520 | 1700 | 45 | C | |
5/520 | ePM10 60% | M5 | 592 | 490 | 520 | 2800 | 45 | C | |
5/520 | ePM10 60% | M5 | 592 | 287 | 520 | 1700 | 45 | C | |
5/370 | ePM10 60% | M5 | 592 | 592 | 370 | 3400 | 55 | >1200 | E |
5/370 | ePM10 60% | M5 | 490 | 592 | 370 | 2800 | 55 | E | |
5/370 | ePM10 60% | M5 | 287 | 592 | 370 | 1700 | 55 | E | |
5/370 | ePM10 60% | M5 | 592 | 490 | 370 | 2800 | 55 | E | |
5/370 | ePM10 60% | M5 | 592 | 287 | 370 | 1700 | 55 | E | |
6/640 | ePM2,5 50% | M6 | 592 | 592 | 640 | 3400 | 70 | 1212 | C |
6/640 | ePM2,5 50% | M6 | 490 | 592 | 640 | 2800 | 70 | C | |
6/640 | ePM2,5 50% | M6 | 287 | 592 | 640 | 1700 | 70 | C | |
6/640 | ePM2,5 50% | M6 | 592 | 490 | 640 | 2800 | 70 | C | |
6/640 | ePM2,5 50% | M6 | 592 | 287 | 640 | 1700 | 70 | C | |
6/520 | ePM2,5 50% | M6 | 592 | 592 | 520 | 3400 | 80 | 1552 | D |
6/520 | ePM2,5 50% | M6 | 490 | 592 | 520 | 2800 | 80 | D | |
6/520 | ePM2,5 50% | M6 | 287 | 592 | 520 | 1700 | 80 | D | |
6/520 | ePM2,5 50% | M6 | 592 | 490 | 520 | 2800 | 80 | D | |
6/520 | ePM2,5 50% | M6 | 592 | 287 | 520 | 1700 | 80 | D | |
6/370 | ePM2,5 50% | M6 | 592 | 592 | 370 | 3400 | 120 | >1900 | E |
6/370 | ePM2,5 50% | M6 | 490 | 592 | 370 | 2800 | 120 | E | |
6/370 | ePM2,5 50% | M6 | 287 | 592 | 370 | 1700 | 120 | E | |
6/370 | ePM2,5 50% | M6 | 592 | 490 | 370 | 2800 | 120 | E | |
6/370 | ePM2,5 50% | M6 | 592 | 287 | 370 | 1700 | 120 | E | |
7/640 | ePM1 60% | F7 | 592 | 592 | 640 | 3400 | 85 | 1165 | C |
7/640 | ePM1 60% | F7 | 490 | 592 | 640 | 2800 | 85 | C | |
7/640 | ePM1 60% | F7 | 287 | 592 | 640 | 1700 | 85 | C | |
7/640 | ePM1 60% | F7 | 592 | 490 | 640 | 2800 | 85 | C | |
7/640 | ePM1 60% | F7 | 592 | 287 | 640 | 1700 | 85 | C | |
7/520 | ePM1 60% | F7 | 592 | 592 | 520 | 3400 | 105 | 1528 | D |
7/520 | ePM1 60% | F7 | 490 | 592 | 520 | 2800 | 105 | D | |
7/520 | ePM1 60% | F7 | 287 | 592 | 520 | 1700 | 105 | D | |
7/520 | ePM1 60% | F7 | 592 | 490 | 520 | 2800 | 105 | D | |
7/520 | ePM1 60% | F7 | 592 | 287 | 520 | 1700 | 105 | D | |
7/370 | ePM1 60% | F7 | 592 | 592 | 370 | 3400 | 150 | >2050 | E |
7/370 | ePM1 60% | F7 | 490 | 592 | 370 | 2800 | 150 | E | |
7/370 | ePM1 60% | F7 | 287 | 592 | 370 | 1700 | 150 | E | |
7/370 | ePM1 60% | F7 | 592 | 490 | 370 | 2800 | 150 | E | |
7/370 | ePM1 60% | F7 | 592 | 287 | 370 | 1700 | 150 | E | |
9/640 | ePM1 85% | F9 | 592 | 592 | 640 | 3400 | 200 | >2400 | E |
9/640 | ePM1 85% | F9 | 490 | 592 | 640 | 2800 | 200 | E | |
9/640 | ePM1 85% | F9 | 287 | 592 | 640 | 1700 | 200 | E | |
9/640 | ePM1 85% | F9 | 592 | 490 | 640 | 2800 | 200 | E | |
9/640 | ePM1 85% | F9 | 592 | 287 | 640 | 1700 | 200 | E | |
9/520 | ePM1 85% | F9 | 592 | 592 | 520 | 3400 | 230 | >2400 | E |
9/520 | ePM1 85% | F9 | 490 | 592 | 520 | 2800 | 230 | E | |
9/520 | ePM1 85% | F9 | 287 | 592 | 520 | 1700 | 230 | E | |
9/520 | ePM1 85% | F9 | 592 | 490 | 520 | 2800 | 230 | E | |
9/520 | ePM1 85% | F9 | 592 | 287 | 520 | 1700 | 230 | E |
In cold winter months, our energy and heat needs increase as the temperature drops outside. The sudden temperature change can lead to a sharp increase in pollution levels in the outdoor air. In addition, the cold itself means that we spend even more time indoors, which brings us closer to each other. Many don't understand how it affects us and our indoor environment.
Commercial and Public buildings Air cleaners and air purifiers Air qualityCamfil is an official sponsor of the Swedish pavilion by providing advanced clean air solutions that ensure better indoor air quality for visitors. EXPO 2020 in Dubai has started on October 1st, 2021 and will conclude on March 31st, 2022.
Innovation Technology and Research Take a breath Education and Experience Sustainability Air qualityCamfil is in the vanguard of a growing international movement to reduce the negative health effects of polluted air. As a leader in clean air solutions, we actively inform and educate customers, decision-makers, and the general public about threatening air pollutants and the tangible benefits of effective air filtration and high indoor air quality.
Take a breath Virus Contamination Control Commercial and Public buildings Air cleaners and air purifiers Air quality
Case Study: Indoor Air Quality Worth The Investment. This major bank is one of the world‘s largest financial institutions. Norland Managed services are the Facilities Management provider for their 600,000 square feet London office building, in central London.
Case Study: Filter Savings At Frozen Food Manufacturer. Three air handling units supplied air to critical processing areas in one of the USA's largest frozen food manufacturing facilities. The pre and final filter combination saved the plant over $33,000 per year.
Dalkia, a leader in the French gas turbine market, launched a national comparative test for various air intake filters, including Camfil's Hi-Flo pre-filters and CamGT EPA filters, to increase power production for their 10 GE LM6000 gas turbines.
Some processes are more sensitive than others. If you work in the food and beverage or life science industries, you know how tough the demands on clean air are. To be sure you have the right filter, look for the ProSafe symbol.
Life science and healthcare Standard and regulations Food and beverage