Item Type | ISO/PM rating | Filter Class EN779 | Filter Class ASHRAE | Width (mm) | Height (mm) | Depth (mm) | Airflow (m3/h) | Pressure drop Initial (Pa) | Energy (kWh/year) | Energy Class (Eurovent) |
---|---|---|---|---|---|---|---|---|---|---|
30/30 24x24x1 | ePM10 50% | G4 | MERV 8 | 594 | 594 | 22 | 2380 | 60 | >1100 | E |
30/30 24x20x1 | ePM10 50% | G4 | MERV 8 | 495 | 594 | 22 | 1980 | 60 | E | |
30/30 20x20x1 | ePM10 50% | G4 | MERV 8 | 495 | 495 | 22 | 1650 | 60 | E | |
30/30 25x20x1 | ePM10 50% | G4 | MERV 8 | 495 | 622 | 22 | 2065 | 60 | E | |
30/30 20x16x1 | ePM10 50% | G4 | MERV 8 | 394 | 495 | 22 | 1326 | 60 | E | |
30/30 25x16x1 | ePM10 50% | G4 | MERV 8 | 394 | 622 | 22 | 1650 | 60 | E | |
30/30 24x12x1 | ePM10 50% | G4 | MERV 8 | 292 | 594 | 22 | 1190 | 60 | E | |
30/30 24x24x2 | ePM10 50% | G4 | MERV 8 | 594 | 594 | 44 | 3400 | 70 | >1100 | E |
30/30 20x20x2 | ePM10 50% | G4 | MERV 8 | 495 | 495 | 44 | 2363 | 70 | E | |
30/30 25x20x2 | ePM10 50% | G4 | MERV 8 | 495 | 622 | 44 | 2958 | 70 | E | |
30/30 24x20x2 | ePM10 50% | G4 | MERV 8 | 495 | 594 | 44 | 2839 | 70 | E | |
30/30 24x18x2 | ePM10 50% | G4 | MERV 8 | 444 | 594 | 44 | 2550 | 70 | E | |
30/30 25x16x2 | ePM10 50% | G4 | MERV 8 | 394 | 622 | 44 | 2363 | 70 | E | |
30/30 20x16x2 | ePM10 50% | G4 | MERV 8 | 394 | 495 | 44 | 1870 | 70 | E | |
30/30 24x16x2 | ePM10 50% | G4 | MERV 8 | 394 | 594 | 44 | 2270 | 70 | E | |
30/30 20x14x2 | ePM10 50% | G4 | MERV 8 | 343 | 495 | 44 | 1658 | 70 | E | |
30/30 24x12x2 | ePM10 50% | G4 | MERV 8 | 289 | 594 | 44 | 1700 | 70 | E | |
30/30 25x25x4 | ePM10 50% | G4 | MERV 8 | 619 | 619 | 95 | 3689 | 65 | D | |
30/30 24x24x4 | ePM10 50% | G4 | MERV 8 | 594 | 594 | 95 | 3400 | 65 | 1098 | D |
30/30 25x20x4 | ePM10 50% | G4 | MERV 8 | 492 | 619 | 95 | 2958 | 65 | D | |
30/30 24x20x4 | ePM10 50% | G4 | MERV 8 | 492 | 594 | 95 | 2839 | 65 | D | |
30/30 20x20x4 | ePM10 50% | G4 | MERV 8 | 492 | 492 | 95 | 2363 | 65 | D | |
30/30 25x16x4 | ePM10 50% | G4 | MERV 8 | 390 | 619 | 95 | 2363 | 65 | D | |
30/30 20x16x4 | ePM10 50% | G4 | MERV 8 | 390 | 492 | 95 | 1870 | 65 | D | |
30/30 24x12x4 | ePM10 50% | G4 | MERV 8 | 289 | 594 | 95 | 1700 | 65 | D |
Choosing the right prefiltration strategy can optimize the performance of your ventilation system and reduce your environmental impact.
Commercial and Public buildings Air qualityCamfil is an official sponsor of the Swedish pavilion by providing advanced clean air solutions that ensure better indoor air quality for visitors. EXPO 2020 in Dubai has started on October 1st, 2021 and will conclude on March 31st, 2022.
Innovation Technology and Research Take a breath Education and Experience Sustainability Air qualityS.Silpa Co., Ltd., Thailand faced constant odor nuisance and high VOC levels in their factory. This is due to the usage of various chemicals in the printing process that generate volatile organic compounds (VOCs) when exposed to heat, such as thinner solutions, alcohols, inks, cleaning solvents, vinyl sheets.
Restaurants have odours coming from a variety of sources and they all have one thing in common, they spread 'air pollution'. Odours are one of the leading causes of air pollution at restaurants or food courts and the odour profile from a kitchen depends on various factors.
Food and beverage Commercial and Public buildings Air quality
Air quality has always been an important factor for hotels, whether it has been removing odours from kitchen extracts to ensuring a clean environment by reducing particulate levels.
Virus Contamination Control Commercial and Public buildings Air cleaners and air purifiers Air quality
Premium air filters help global grocer significantly improve air quality and reduce maintenance costs, waste and storage
Case Study: Bottled Water Producer Reduces Labour And Waste. One of the largest global food companies and a global leader in the bottled water industry, read about how this company turned to Camfil to help meet its strong commitment to health, hydration and the environment in particular.
Case Study: Filter Savings At Frozen Food Manufacturer. Three air handling units supplied air to critical processing areas in one of the USA's largest frozen food manufacturing facilities. The pre and final filter combination saved the plant over $33,000 per year.