HEPA H13 filter for supply & exhaust air systems with low to medium air velocities (1,8 m/s). Stable galvanized steel frame, stainless steel available on request.
Item Type | Filter Class EN1822 | Width (mm) | Height (mm) | Depth (mm) | Airflow (m3/h) | Pressure drop Average (Pa) |
---|---|---|---|---|---|---|
CED11-305x305x150-P0 | E11 | 305 | 305 | 150 | 290 | 125 |
CED11-457x457x150-P0 | E11 | 457 | 457 | 150 | 660 | 125 |
CED11-575x575x150-P0 | E11 | 575 | 575 | 150 | 1055 | 125 |
CED11-305x610x150-P0 | E11 | 305 | 610 | 150 | 590 | 125 |
CED11-610x610x150-P0 | E11 | 610 | 610 | 150 | 1190 | 125 |
CED11-762x610x150-P0 | E11 | 762 | 610 | 150 | 1490 | 125 |
CED11-914x610x150-P0 | E11 | 914 | 610 | 150 | 1790 | 125 |
CED11-1219x610x150-P0 | E11 | 1219 | 610 | 150 | 2380 | 125 |
CEX11-305x305x150-P0 | E11 | 305 | 305 | 150 | 380 | 125 |
CEX11-457x457x150-P0 | E11 | 457 | 457 | 150 | 865 | 125 |
CEX11-575x575x150-P0 | E11 | 575 | 575 | 150 | 1385 | 125 |
CEX11-305x610x150-P0 | E11 | 305 | 610 | 150 | 770 | 125 |
CEX11-610x610x150-P0 | E11 | 610 | 610 | 150 | 1560 | 125 |
CEX11-762x610x150-P0 | E11 | 762 | 610 | 150 | 1950 | 125 |
CEX11-914x610x150-P0 | E11 | 914 | 610 | 150 | 2335 | 125 |
CEX11-1219x610x150-P0 | E11 | 1219 | 610 | 150 | 3120 | 125 |
CEG11-305x610x292-P0 | E11 | 305 | 610 | 292 | 950 | 125 |
CEG11-457x610x292-P0 | E11 | 457 | 610 | 292 | 1420 | 125 |
CEG11-610x610x292-P0 | E11 | 610 | 610 | 292 | 1900 | 125 |
CEG11-762x610x292-P0 | E11 | 762 | 610 | 292 | 2380 | 125 |
CET11-305x610x292-P0 | E11 | 305 | 610 | 292 | 1190 | 125 |
CET11-457x610x292-P0 | E11 | 457 | 610 | 292 | 1780 | 125 |
CET11-610x610x292-P0 | E11 | 610 | 610 | 292 | 2380 | 125 |
CET11-762x610x292-P0 | E11 | 762 | 610 | 292 | 2975 | 125 |
Restaurants have odours coming from a variety of sources and they all have one thing in common, they spread 'air pollution'. Odours are one of the leading causes of air pollution at restaurants or food courts and the odour profile from a kitchen depends on various factors.
Food and beverage Commercial and Public buildings Air qualityGO fit Sports Centers were forced to close all its centers in March 2020 when the state of emergency was announced in Spain to tackle the COVID-19 pandemic. Ingesport Group the parent company of the GO fit brand, contacted us to provide a comprehensive solution to reduce the risks of airborne transmission and infection, facilitating a safer indoor environment.